Panels

HEPHAIS 128 – Intelligent/ interactive compact control panel

NTELLIGENT/INTERACTIVE COMPACT CONTROL PANEL, 128 ADDRESSES, 2 loops or 4 spur circuits (open circuit with max 32 addresses), 99 ZONES, 1000 memory events, 1 monitored sounders line + 5 programmable output relays, 1xRS232 serial output for printer or remote control panel, 2 programmable inputs. The panel can be set by keyboard or software. Needs 2 internal batteries 12V/7Ah. EN54-2, EN54-4, CE according to CPD

HEPHAIS 1600-400/L – Modular intelligent interactive fire control panel

 

MODULAR INTELLIGENT/INTERACTIVE FIRE CONTROL PANEL MAX 1600 POINTS, 16 LOOPS – supplied as standard for 400 points on 2 master loops (max 200 addresses/loop) or 4 spur circuits, expandable up to 7 x MG2B ( loop boards), EN54-2, EN 54-4, in large box with integrated front panel, 1000 Zones, 2700 memory events, 2 monitored sounders lines + 3 programmable output relays, 1xRS232 serial output for printer and 1xRS485 serial output for remote control panel, 4 programmable inputs, RS422 JBUS monitoring output, networkable with MG NET board. Needs 2 internal batteries 12V/17Ah. EN54-2, EN54-4, CE according to CPD

ALPHA RE – Remote user interface panel

REMOTE USER INTERFACE PANEL with serial 485 connection, alphanumeric display LCD 160 characters and keyboard

TELEHEPHAIS 1600 – Software programming tool for hephais 1600

SOFTWARE PROGRAMMING TOOL  for HEPHAIS 1600

 

 TELEHEPHAIS 128 – Software programming tool

SOFTWARE PROGRAMMING TOOL  for HEPHAIS 128, uploading/downloading

 


Fire detectors

OA05 – Intelligent / Interactive optical smoke detector

INTELLIGENT/INTERACTIVE OPTICAL SMOKE DETECTOR, microprocessor based , 1 programmable remote alarm indicator output, 8 levels sensitivity setting, EN54-7, CE according to CPD 

 TA05 – Intelligent interactive heat detector

INTELLIGENT/INTERACTIVE HEAT DETECTOR, static or/and rate of rise, microprocessor based 1 , programmable remote alarm indicator output, 6 levels sensitivity setting, EN54-5, CE according to CPD

ICC05 – Plug in isolator board

PLUG IN ISOLATOR BOARD for 05 detectors (to be plugged in S05SE)  


Interface loop units

MAY1 – Zone interface module

 ADDRESSABLE ZONE INTERFACE MODULE  with back box, for max 32 conventional points

MBA95 – Zone interface module

 ADDRESSABLE ZONE INTERFACE MODULE  with backbox, for max 32 conventional    points, isolator integrated,opto-isolated on the secondary line, EN54-17, EN54-18,  EN54-13 CE according to CPD

ETC05-B – Input / output module

 ADDRESSABLE INPUT/OUTPUT MODULE  with backbox, isolator integrated, NO or NC monitoring  for input , relay output NO-NC 30V/1A, EN54-17, EN54-18 CE according to CPD (exists also in RAIL  DIN version)

ET4C05-B – 4 inpu output module

 ADDRESSABLE 4 INPUT/OUTPUT MODULE  with backbox, isolator integrated, NO or NC  monitoring for input , relay output NO-NC 30V/1A, EN54-17, EN54-18 CE according to CPD

EDL – 2 Monitored input + 1 out put

 ADDRESSABLE 2 MONITORED INPUT + 1 MONITORED LINE OUTPUT permits to manage NO or NC  for the monitored inputs and use monitored sounders line for outputs, EN54-17, EN54-18, CE  according to CPD

ED4L – 8 monitored input + 4 monitored line output

 ADDRESSABLE 8 MONITORED INPUT + 4 MONITORED LINE OUTPUT permits to manage NO or NC for the  monitored inputs and use monitored sounders line for outputs, EN54-17, EN54-18, CE according to CPD


 

Loop sounders 

 AVSA05/R – Addressable high powered piezoelectric sounder

ADDRESSABLE HIGH POWERED PIEZOELECTRIC SOUNDER for indoor use red colour), integrated isolator, possibility to select 6 tones, 95db@1m, lateral hearings, loop powered, for HEPHAIS 1600 range

AVSA05/W – Addressable high powered piezoelectric sounder

ADDRESSABLE HIGH POWERED PIEZOELECTRIC SOUNDER for indoor use (white colour), integrated isolator, possibility to select 6 tones, 95db@1m, lateral hearings, loop powered, for HEPHAIS 1600 range