November 23, 2016

Conventional Systems

Panels

ALPHA 2 – 2 zones fire detection conventional panel

alpha-2

2 ZONES FIRE DETECTION CONVENTIONAL PANEL, max 32 detectors and/or MCP per line. Alarm/fault output relays, 1 monitored sounders line + 3 output relays and 1 programmable open collector. Alarm prealarm management. Compact panel not expandable. Needs 2 internal batteries 12V/4Ah

ALPHA 4/8/12 – 12 zones fire detection conventional panel

alpha-4-8-12

12 ZONES FIRE DETECTION CONVENTIONAL PANEL equipped with 4 zones (max 12 zones) – max 32 detectors and/or MCP per line. Alarm/fault relays, 1 monitored sounders line, 4 programmable open collectors, 1 programmable input. Alarm prealarm/management + Day night mode. Expandable panel with availability of 2 rooms for one or two 4 zones expension (EX4A4) or one or two Extinguishing boards (DEAG).EN54-2, EN54-4 AFNOR, BOSEC, CE CPD, EN12094-1 with extinguishing board (DEAG). Needs 2 batteries 12V/7Ah

tr-sdi

TR-SDI – Remote indicator panel

REMOTE INDICATOR PANEL with leds and function keys, to repeat general alarm and fault, local test leds and silence buzzer

TRI 10 – 10 zones remote indicator panel

tri10-2

 10 ZONES REMOTE INDICATOR PANEL with leds and function keys, permits to repeat fire alarm zones, local test leds and silence buzzer


Fire detectors

trc05-tsc05-ta05-dtour_2081

TSC05-BS – Fixed heat detector 

 CONVENTIONAL FIXED HEAT DETECTOR, T° = 75°C, 1 remote led output, EN54-5 , CE according to CPD 

trc05-tsc05-ta05-dtour_2081

 OC05.12 or OC05-.12-AR – Optical smoke detector

 CONVENTIONAL OPTICAL SMOKE DETECTOR, for 12V security type systems, to be used with R05 relay board, alarm latched or autoresettable (AR version)

trc05-nouveau-2010_15267

 TRC05.12 or TRC05.12-AR – Rate of rise + fixed heat detector 

CONVENTIONAL RATE OF RISE + FIXED HEAT DETECTOR, T° = 62°C, + 9°C/min, for 12V security type systems, to be used with R05 relay board, alarm latched or autoresettable (AR version)


Manual call points

DMCL05 – Manual call point

 CONVENTIONAL MANUAL CALL POINT resettable with key without breaking glass,  led and alarm dmcl053resistor integrated, RED colour, EN54-11, CE according to CPD

DMCL05-J – Manual call point

 CONVENTIONAL MANUAL CALL POINT resettable with key without breaking glass, dmcl05-jaune_1184644811led and alarm resistor integrated, YELLOW colour

 DMCL05-B – Manual call point

 CONVENTIONAL MANUAL CALL POINT resettable with key without dmc05-bleubreaking glass, led and alarm resistor integrated, BLUE colour